Teriparatide Lupin

Teriparatide Lupin

teriparatide 250 mcg/ml solution for injection in pre filled pen

The educational materials provided in the following webpages are intended for patients who have been prescribed a medicinal product supplied by Lupin AU by their treating doctors. By entering this website, you agree that you are a patient who is currently using or about to use a medicinal product supplied by Lupin AU for a condition that has been diagnosed by your treating doctor.

 

By continuing, you understand that the educational materials are provided herewith to assist you to use Lupin AU’s product correctly as it is intended.

 

Please always read the Consumer Medicine Information (CMI), instruction manual or pack insert, as applicable, supplied with your medicine in full before use. For any medical information queries or to report an adverse event, please contact Lupin AU on +61 3 9809 7900 or by email at auinfo@lupin.com.au 

 

Do not use Teriparatide Lupin if you have previously received teriparatide therapy for a total of 24 months. This total of 24 months therapy may have been made up of several shorter courses of teriparatide. If you are not sure if you have previously recelved teriparatide, speak to your doctor or pharmacist. You will be required to sign your consent that you understand the 24-month lifetime limit. Keep this consent form as you may need to show this to your doctor in the future. Your pharmacist may also ask to see your consent form.

 

Pack Details

read more

Safety Instructions

read more

Preventive Care

read more

For more detailed information, please refer to the links below

Instructions for Use

Preparing your injection pen before first use

How to administer Teriparatide Lupin

Frequently Asked Questions

What to do if small air bubbles are visible in the cartridge?

+

You can use your pen without any concern. Small air bubbles will not affect the dose or cause any harm.

What to do if solution is not clear, colourless or free of particles?

+

Do not use the injection pen. Return it to your pharmacist, or contact Lupin AU Customer Service on 03 9809 7900.

What to do if, while preparing the pen for first use, no solution is expelled?

+

Perform the "Dialling the Dose for First Injection" step again. Continue until a few drops of solution are expelled.

What to do if the dose activator is blocked or you have not injected the full dose?

+

Do not give a second injection the same day. Proceed with your regular injection the next day. Make sure you turn the dose knob to the hard stop and the figure “80” is fully visible and centred in the dose window with the white mark aligned in the window notch.

What to do if after injection, a small amount of solution is visible on the needle?

+

This is normal and can be expected. The pen can continue to be used.

What to do if only a partial injection occurred and the full dose has not been injected?

+

Do not give a second injection the same day. Proceed with your regular injection the next day. Before injecting, make sure you turn the dose knob to the hard stop and the figure “80” is fully visible and centred in the dose window with the white mark aligned in the window notch. Do not stop turning the dose knob at the arrow – continue turning until the “80” is fully visible. 
NOTE: The “80” refers to the dose of 80 microlitres which contains 20 micrograms of teriparatide.

What to do if you accidently tried to inject without a needle attached?

+

Attach a needle. You will observe some drops coming out. The pen is now ready for use again. Set the dose and inject.

What to do if injection pen is damaged or spillage from the pen is observed when not in use?

+

Do not use the injection pen. Return it to your pharmacist, or contact Lupin AU Customer Service on 03 9809 7900.

What to do if needle cannot be attached?

+

Ensure the correct needle type is being used (refer to the "Instructions for Use" in the Consumer Medicine Information, or "Pack Details" above, or the "Preparing your injection pen before first use" video). Try another needle instead. If the second needle cannot be attached either, contact Lupin AU Customer Service on 03 9809 7900.

What to do if needle is broken, curved or kinked?

+

Discard and use another needle.